Concrete Column P-M Interaction Diagram (ACI 318-19)
Introduction
A concrete column rarely carries axial load alone. Frame action, eccentric beam reactions and lateral loads add bending, and the more a column bends, the less axial load it can take. The P-M interaction diagram, also called the column interaction diagram, maps that trade-off: every combination of axial strength and bending strength the cross section can develop, from pure compression to pure tension.
In this post, we explain how ACI 318-19 builds the diagram from strain compatibility, what its key points mean, how the strength reduction factor φ changes along it, and how each load combination is checked against it. Then we solve an example with CalcBook's Interaction (P-M) Diagram module.

How to Read a P-M Interaction Diagram
Axes: the diagram plots the design bending strength φMn across and the design axial strength φPn up, with compression positive. The curve is the design strength envelope. A factored demand (Mu, Pu) inside it is OK, and one outside it is not.
One point per strain state: each point on the curve comes from one neutral axis depth, c. The strain at the extreme compression fiber is 0.003 (ACI 318-19 Section 22.2.2.1), and strains vary linearly with the distance from the neutral axis (Section 22.2.1.2).
Concrete: its tensile strength is neglected (Section 22.2.2.2). In compression, a stress of 0.85f′c acts over a block of depth a = β1c (Section 22.2.2.4.1). β1 comes from Table 22.2.2.4.3: 0.85 up to 4,000 psi, then 0.05 less for each 1,000 psi, down to 0.65 at 8,000 psi.
Steel: each bar layer carries fs = Esεs, up to fy (Section 20.2.2.1), with Es = 29,000 ksi (Section 20.2.2.2).
Equilibrium: summing the concrete and bar forces gives Pn, and summing their moments about the section's mid-depth gives Mn. Moving the neutral axis from deep (the whole section in compression) to shallow (most of the steel in tension) traces the whole curve.
The Key Points on the Diagram
A handful of strain states mark the shape of the curve. CalcBook labels them A to F:
A, pure compression: the whole section is in compression, the concrete at 0.85f′c and the steel at fy. Po = 0.85f′c(Ag − Ast) + fyAst (Eq. 22.4.2.2).
B, compression-controlled cap: to allow for accidental eccentricity, ACI 318-19 limits Pn to Pn,max = 0.80Po for tied columns and 0.85Po for spiral columns (Table 22.4.2.1). That cap is the flat top of the diagram, and B is where the curve drops below it.
C, zero tension-steel strain: the neutral axis sits at the extreme layer of steel (c = d1), so those bars carry no stress.
D, balanced: the concrete reaches 0.003 just as the extreme tension steel yields, εs1 = −εty, where εty = fy/Es (Section 21.2.2.1).
E, tension-controlled limit: the net tensile strain in the extreme tension steel reaches εt = εty + 0.003 (Table 21.2.2), and φ reaches 0.90. Before ACI 318-19, this limit was a fixed 0.005. For Grade 60 steel it is now 0.00507, and higher grades push it further.
Pure bending: between E and F, the curve crosses P = 0. That's the section's bending strength with no axial load, as if it were a beam.
F, pure tension: all the steel yields in tension. Pnt = fyAst (Eq. 22.4.3.1), with φ = 0.90. CalcBook plots tension as negative P.
The Strength Reduction Factor φ
ACI 318-19 Table 21.2.2 sets φ by the net tensile strain εt in the extreme tension steel:
Compression-controlled, εt ≤ εty: φ = 0.65 for tied columns, or 0.75 with spirals.
Tension-controlled, εt ≥ εty + 0.003: φ = 0.90.
Transition: φ = 0.65 + 0.25(εt − εty)/0.003 for ties, or 0.75 + 0.15(εt − εty)/0.003 for spirals.
That's why the design curve bends between D and E. On the nominal curve, the largest moment is near the balanced point. Past it, φ climbs from 0.65 to 0.90, so the design bending strength keeps growing until the tension-controlled limit.
Checking the Load Combinations
Each load combination gives a factored pair (Mu, Pu), and each pair is a point on the same plot. The column works when every point lies inside the curve.
To measure how close a point is, draw a ray from the origin through it. Along that ray the eccentricity, e = Mu/Pu, stays the same, and the ray meets the curve at the capacity (φMn, φPn) for that eccentricity. The radial ratio is the demand over that capacity, Mu/φMn = Pu/φPn. A ratio of 1.0 is on the curve, and less than 1.0 is inside it.
The combination with the most axial load isn't always the one that governs. Below the balanced point, axial compression adds bending strength, so with the same moment, less axial load (as in 0.9D + W) puts the point closer to the curve.
Important Details to Be Aware of
Reinforcement limits: ACI 318-19 Section 10.6.1.1 requires 0.01Ag ≤ Ast ≤ 0.08Ag for columns. CalcBook checks it with point A.
Bending axis: a rectangular column has a different diagram about each axis. Choose X or Y under Bending Axis.
Bars inside the compression block: a compression bar inside the stress block displaces concrete that the 0.85f′c block already counts, so CalcBook takes its force as (fs − 0.85f′c)As.
Design, nominal or both: the Diagram Display input switches the plot between the design curve (with φ), the nominal curve, or both together.
Example Problem (Solved with CalcBook)
Problem statement: An 18 in. × 18 in. tied concrete column (f′c = 5,000 psi) has eight No. 9 Grade 60 bars, three on each face, with No. 4 ties and 1-1/2 in. of clear cover. It bends about its X axis. The service loads are an axial load of D = 200 kips and L = 80 kips, and a moment of D = 30 kip-ft, L = 25 kip-ft and W = 200 kip-ft. Build the design interaction diagram and check the column for the ASCE 7-22 LRFD load combinations.
Step 1: Design Inputs
In CalcBook's Interaction (P-M) Diagram module, choose the column shape, the transverse reinforcement and the bending axis, then enter the section, the bars and the materials. The bar counts include the corner bars, so three bars in each direction make eight bars:
Ast = Ab(2nbar,x + 2nbar,y − 4) = 1.00 in.² × (2 × 3 + 2 × 3 − 4) = 8.00 in.²
Ag = bh = 18 in. × 18 in. = 324 in.²
ρ = Ast/Ag = 8.00 in.²/324 in.² = 0.025, between 0.01 and 0.08
The bars sit in three layers. Measured from the compression face:
d3 = 1.5 in. + 0.5 in. + 1.128 in./2 = 2.56 in. (three bars)
d2 = h/2 = 9.00 in. (two bars)
d1 = 18 in. − 2.56 in. = 15.44 in. (three bars, the extreme tension layer)
For f′c = 5,000 psi, β1 = 0.85 − 0.05(5,000 − 4,000)/1,000 = 0.80.

The cross section next to the diagram at the top of this post is CalcBook's to-scale drawing of these inputs.
Step 2: Loads and Load Combinations
The moments go under Flexural Demand and the axial loads under Compressive Demand, by load type. CalcBook runs all twelve ASCE 7-22 LRFD combinations and marks the one that governs. Here it's LC4a (1.2D + W + L + 0.5Lr):
Pu = 1.2(200 kips) + 80 kips = 320 kips
Mu = 1.2(30 kip-ft) + 200 kip-ft + 25 kip-ft = 261 kip-ft

Step 3: Pure Compression and the Cap (Points A and B)
Po = 0.85f′c(Ag − Ast) + fyAst = 0.85 × 5 ksi × (324 in.² − 8.00 in.²) + 60 ksi × 8.00 in.² = 1,823 kips (Eq. 22.4.2.2)
Pn,max = 0.80Po = 0.80 × 1,823 kips = 1,458.4 kips (Table 22.4.2.1, ties)
φPn,max = 0.65 × 1,458.4 kips = 947.96 kips (compression-controlled, Table 21.2.2)
That's points A and B, the flat top of the diagram at 948.0 kips. B is where the curve drops below the cap, at c = 18.95 in. and φMn = 130.6 kip-ft.

CalcBook checks the steel ratio in the same step (0.025, within 0.01 to 0.08), and its φ figure shows the compression-controlled, transition and tension-controlled zones.
Step 4: The Balanced Point by Hand (Point D)
At the balanced point, the concrete reaches 0.003 as the extreme tension layer yields:
εty = fy/Es = 60 ksi/29,000 ksi = 0.00207 (Section 21.2.2.1)
c = 0.003d1/(0.003 + εty) = 0.003 × 15.44 in./(0.003 + 0.00207) = 9.14 in.
a = β1c = 0.80 × 9.14 in. = 7.31 in.
The strain runs linearly from 0.003 at the compression face to −εty at d1, so each layer's strain is εs = 0.003 − (0.003 + εty)d/d1:
Top layer, d3 = 2.56 in.: εs3 = 0.003 − 0.00507 × 2.56/15.44 = 0.00216, more than εty, so fs3 = 60 ksi. These bars are inside the stress block, so Fs3 = (60 ksi − 0.85 × 5 ksi) × 3.00 in.² = 167.25 kips.
Middle layer, d2 = 9.00 in.: εs2 = 0.003 − 0.00507 × 9.00/15.44 = 0.000045, so fs2 = 0.000045 × 29,000 ksi = 1.3 ksi and Fs2 = 1.3 ksi × 2.00 in.² = 2.6 kips.
Bottom layer, d1 = 15.44 in.: εs1 = −0.00207, yielding in tension, so Fs1 = −60 ksi × 3.00 in.² = −180.0 kips.
Concrete: Cc = 0.85f′cab = 0.85 × 5 ksi × 7.31 in. × 18 in. = 559.2 kips.
Pn = Cc + Fs3 + Fs2 + Fs1 = 559.2 + 167.25 + 2.6 − 180.0 = 549.05 kips
φPn = 0.65 × 549.05 kips = 356.9 kips (εt = εty, compression-controlled)

Taking moments about mid-depth, h/2 = 9.00 in.:
Mn = Cc(h/2 − a/2) + Fs3(h/2 − d3) + Fs2(h/2 − d2) + Fs1(h/2 − d1)
Mn = 559.2 kips × 5.345 in. + 167.25 kips × 6.44 in. + 2.6 kips × 0 + (−180.0 kips) × (−6.44 in.) = 5,225.2 kip-in. = 435.4 kip-ft
φMn = 0.65 × 435.4 kip-ft = 283.0 kip-ft
CalcBook gets 356.85 kips and 282.98 kip-ft for point D, the same to rounding.

Step 5: The Tension-Controlled Limit (Point E) and the Rest of the Curve
Under ACI 318-19, the tension-controlled limit depends on the steel grade:
εt = εty + 0.003 = 0.00207 + 0.003 = 0.00507 (Table 21.2.2)
c = 0.003 × 15.44 in./(0.003 + 0.00507) = 5.74 in.
With the same steps as point D and φ = 0.90, CalcBook gets φPn = 183.7 kips and φMn = 327.1 kip-ft.

The other points follow the same way. At C, c = d1 = 15.44 in., which gives φPn = 764.5 kips and φMn = 202.9 kip-ft. At F, Pnt = −fyAst = −60 ksi × 8.00 in.² = −480 kips, and φPnt = 0.90 × (−480 kips) = −432 kips. Between E and F, the curve crosses P = 0 at about φMn = 250 kip-ft, the column's pure bending strength (by strain compatibility, c = 3.76 in. and εt = 0.0093 there, so φ = 0.90).
Step 6: Check Every Load Combination
CalcBook draws the design curve through points A to F, plots the governing combination (the green ✕ on the diagram at the top of this post) and lists the points:

LC4a, at 261 kip-ft and 320 kips, plots inside the curve. Its ray from the origin meets the curve between D and E. Taking the capacity on the straight line from D (283.0 kip-ft, 356.9 kips) to E (327.1 kip-ft, 183.7 kips), the ray reaches it at (284.9 kip-ft, 349.3 kips), so:
Radial ratio = Mu/φMn = 261 kip-ft/284.9 kip-ft = 0.92 (and Pu/φPn = 320 kips/349.3 kips = 0.92)
LC4b gives the same point here, since there's no snow load. The other combinations sit farther inside the curve. LC5 (0.9D + W) has the least axial load, 180 kips with 227 kip-ft, and its ratio is 0.73.

Result
The 18 in. × 18 in. column with eight No. 9 bars works for every ASCE 7-22 combination. LC4a governs, at about 92% of the capacity along its ray, and CalcBook reports Design OK.
Conclusion
A P-M interaction diagram turns a column check into a picture. Strain compatibility sets each point, φ follows the strain in the tension steel, and every load combination becomes a point that has to land inside the curve. ACI 318-19's tension-controlled limit, εty + 0.003, now moves with the steel grade.
CalcBook's Interaction (P-M) Diagram module builds the design or nominal curve for rectangular and circular columns with ties or spirals, about either axis of a rectangular column, in US or metric units. It runs the ASCE 7 load combinations and shows each key point step by step with its ACI 318-19 reference. Change the bars, the section or the loads, and the diagram redraws.
Related design examples: concrete column axial design, concrete beam design and concrete shear wall design.